Fetal Distress

Fetal Distress Fetal Distress - Common Medical Malpractice Claims | Legal advice for people affected by medical malpractice.

Fetal distress is an umbrella term used to describe warning signs that indicate a fetus may be experiencing health problems. Fetal distress can occur quickly, with little warning. If the mother and her fetus are not properly monitored, complications can be overlooked. Fetal distress most commonly occurs shortly before or during birth. In many cases, fetal distress can be treated by emergency delivery using forceps, a vacuum extractor, or a Caesarean section (C-section).

Causes of Fetal Distress

There are several complications that can lead to fetal distress, including:

Signs of Fetal Distress

Warning signs that can suggest fetal distress include:

Diagnosing Fetal Distress

The most common ways to determine fetal distress before or during childbirth is through fetal heart monitoring (FHM) and close observation of uterine contractions. A steady heart rate is a strong indicator of proper blood flow and overall health. During labor, it is often recommended to check and record the fetal heart rate every 30 minutes. This consistent monitoring can help identify changes in fetal heart rate that may imply fetal distress. Monitoring can be performed in a variety of birth settings, using a variety of tools.

Fetal distress monitoring methods involve:

External Fetal Monitoring

This type of monitoring records the fetal heart rate from outside the mother’s abdomen. The most basic external fetal monitor is a fetoscope, or a specialized stethoscope.Electric hand-held Doppler devices are also used to provide ultrasounds that may help prevent fetal distress.

Internal Fetal Monitoring

Internal monitoring helps identify fetal distress by using a wire electrodethat is typically attached to the head of the fetus through the opening of the mother’s cervix. Contraction strength can be measured by the insertion of a catheter-shaped device into the uterus.

Uterine Contraction Monitoring

A tocodynamometer is a pressure-sensitive device that measures the frequency, length, and strength of contractions. It also measures fetal heart rate for comparison of the direct effects of contractions on fetal heart rate, which can often illustrate fetal distress.

The American Pregnancy Association recommends performing the Fetal Non-Stress Test (NST) after 28 weeks gestation. This external monitoring method uses two belts to detect fetal heart rate and contractions in relation to the movement of the fetus. The NST indicates adequate blood flow and oxygen supply to the fetus, which is essential for preventing fetal distress.

Failure to Treat Fetal Distress

It is critical that an expecting mother and her fetus are properly monitored before and during birth. Untreated fetal distress can have devastating results. Fetal distress may causehypoxia, or a lack of oxygen, that can result in brain damage or infant death.

Long-term effects of fetal distress may include:

 

Sources:

“Human Qualities and Polar Exploration.” Canadian Medical Association Journal 82.22 (1960): 1128. MEDLINE with Full Text.Web. 26 Nov. 2012.
“New fetal distress study results reported from Colorado State University.” Science Letter 21 Dec. 2010: 695. Academic OneFile.Web. 26 Nov. 2012.
Yentis, S M. “Whose Distress Is It Anyway? ‘Fetal Distress’ And The 30-Minute Rule.” Anaesthesia 58.8 (2003): 732-733. MEDLINE with Full Text.Web. 26 Nov. 2012.